Cable wiring – Rockwell Automation 1326-xxxx Cables with Right Angle Connectors User Manual
Page 3

Publication 1326A-IN024B-EN-P - May 2007
Right-angle Connection for Series B 1326 Cables 3
Cable Wiring
Connector wiring pinouts and diagrams are provided in these cables.
1326-CCUT-RAL-xxx and 1326-CCUT-RBL-xxx Wiring
This table provides wiring information for the 1326-CCUT-RAL,
1326-CCUT-RBL motor feedback (resolver) cables.
1326-CCUT-RAL, 1326-CCUT-RBL Cable Wiring Diagram
Signal
Wire Color
Gauge
mm
2
(AWG)
Connector Pin
1394 Terminal
Axis_0_R1
Black
0.518 (20)
A
1
Axis_0_R2
White
0.518 (20)
B
6
Shield
0.518 (20)
No connection
2
Axis_0_S1
Black
0.518 (20)
D
3
Axis_0_S3
Red
0.518 (20)
E
8
Shield
0.518 (20)
No connection
7
Axis_0_S4
Black
0.518 (20)
H
9
Axis_0_S2
Green
0.518 (20)
G
4
Shield
0.518 (20)
No connection
5
Overall shield
N/A
No connection
10
1
6
2
Pair #1: Black
Pair #1: White
Shield
3
8
7
Pair #2: Black
Pair #2: Red
Shield
9
4
5
Pair #3: Black
Pair #3: Green
Shield
10
Shield
A
B
D
E
H
G
C
F
I
J
Sealing
Plug