All parameters are specified at 24V, 3.8A, 24Vdc input voltage, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.
8
Rockwell Automation Publication 1606-RM023A-EN-P — January 2014
Bulletin 1606 Switched Mode Power Supplies
7. Efficiency and Power Losses
Input 24Vdc
Efficiency
typ.
90.5%
at 24V, 3.8A
Power losses
typ.
0.7W
at no output load
typ.
5.5W
at
24V,
1.9A
typ.
9.7W
at
24V,
3.8A
Fig. 7-1
Efficiency vs. output current at 24V,
typ.
Fig. 7-2 Losses vs. output current at 24V,
typ.
Efficiency
1
86
88
90
85
91%
4A
2
3
3.5
2.5
87
89
1.5
0.5
Output Current
Power Losses
0
1
2
4A
0
2
6
10
12W
4
3
8
Output Current
Fig. 7-3
Efficiency vs. input voltage at 24V,
3.8A, typ.
Fig. 7-4 Losses vs. input voltage at 24V, 3.8A,
typ.
Efficiency
18
20
22
26
28
32Vdc
91%
88.5
89.5
90.5
90.0
89.0
88.0
24
30
Input Voltage
Power Losses
0
2
4
6
8
10
12W
18
20
24
26
28
32Vdc
30
Input Voltage