Bulletin 1329i ce filter option specifications – Rockwell Automation 1329I CE Filter Option Kit User Manual
Page 8

Publication 1329I-5.4 – January, 2000
P/N 194395 (01)
Copyright 2000 Rockwell International Corporation. Printed in USA
Bulletin 1329I CE Filter
Option Specifications
1329I-NLF1
1329I-NLF3
1329I-JLF1
1329I-JLF3
Input Voltage
115/230 VAC
230/460 VAC
115/230 VAC
230/460 VAC
Input Phases
Single Phase
Three Phase
Single Phase
Three Phase
Frequency
50/60 Hz
Rated Current
14 Amps
9 Amps
14 Amps
9 Amps
Power Dissipation
5 Watts
Leakage Current (Worst Case)
0.5 mA
Weight
0.33 Kg (0.73 lb)
0.45 Kg (0.99 lb)
4.72 Kg (10.41 lb)
4.89 Kg (10.78 lb)
Enclosure
Internal
NEMA 12/IP 65
Operating Temperature
0° to 40°C (32° to 104°F)
Storage Temperature
-40° to 85°C (-40° to 185°F)
Relative Humidity
5% to 95%, non-condensing
Vibration
1 G operational, 2.5 G non-operational
Shock
15 G operational, 30 G non-operational
Altitude
1000 meters (3300 feet) without derating. For every 91.4 meters (300 feet) above
1000 meters, derate current by 1%. Above 3000 meters (10,000 feet), consult your
Allen-Bradley Sales Office.
International Standards and
Approvals
UL
®
LISTE
D 966X
IND CONT EQ
UL508C
UL
®
LISTE
D 966X
IND CONT EQ
C
CSA 22.2
EMC Directive 89/336
LV:
EN 50178, EN 60204
EMC: EN 61800-3, EN 50081-1, EN 50082-2