Rockwell Automation 1394 Terminator User Manual
Installing your 1394 terminator, Installation instructions
 
Publication 1394-6.4 November 1998
Installation Instructions
Installing Your 1394 Terminator
This document illustrates the installation of the 1394 terminator and 
is used in conjunction with the 1394 Digital AC Multi-Axis Motion 
Control System User Manual (publication 1394-5.0).
Installing the 1394 Terminator
To install the 1394 terminator:
1.
Verify that power has been removed from your system.
2.
Attach the terminator to the right most axis module on your 
system and slide the terminator to the left until it locks into place.
Figure 1
Attaching the Terminator
3.
Apply power to your system.
!
ATTENTION: This system may have multiple 
sources of power. More than one disconnect switch 
may be required to de-energize the system. To avoid 
shock hazard or personal injury, assure that all power 
has been removed before proceeding.
!
ATTENTION: This product contains stored energy 
devices. To avoid hazard of electrical shock, verify that 
all voltage on the capacitors has been discharged before 
attempting to service, repair, or remove this unit. You 
should only attempt the procedures in this document if 
you are qualified to do so and familiar with solid-state 
control equipment and the safety procedures in 
publication NFPA 70E.
Terminator
1394 Digital Servo Controller
System Module
Allen-Bradley