Rockwell Automation 1405-M610 Operating Instructions User Manual
Page 7

Publication 1405-IN001B-EN-P - October 2003
Bulletin 1405 (M610) Operating Instructions 7
Temperature Coefficient
< 0.01% / K
Input Impedance (Voltage Inputs)
2 Mohm (Lx to N)
Input Impedance (Current Inputs)
0.01 ohm at 5A
Overload Rating
Voltage 110% (continuous)
Current 200% (continuous)
Frequency Range
47 to 63 Hz
Power Consumption
3W typical
Operating Temperature
+5°C to +50°C (+41°F to +122°F)
Storage Temperature
-20°C to +70°C (-4°F to +158°F)
Protection Class
Enclosure IP 20 (IP 65 with optional protective
hood
(1)
)
Terminals IP 00
Weight
Approximately 0.3 kg
Front Dimensions
96 mm x 96 mm (3.78 in x 3.78 in)
Breakdown Rating
Per DIN 41700
Depth
65 mm (2.56 in)
Panel Mounting
Spring Clamps
Agency Certifications
UL, CE
(1)
The optional hood, catalog number 1405-PRO, can be ordered separately. Contact your Rockwell Automation
distributor for additional information.
Table 3 General Parameters
Parameter
Value
Table 4 Measurement Accuracy and Range
Parameter
Percent of Reading
Nominal Value
Operating Range
Maximum Limit
Volts
±1%
240V rms
10V rms to 347V rms L-N
or 17V rms to 600V rms
L-L
400V rms L-N or 690V
rms L-L
Current
±1%
5 Amps
0.1 Amps to 6 Amps
10 Amps