Rockwell Automation 1395 Reel Tension Paster Adapter User Manual
Page 25

Publication 1395-RTP-5.1 - September 1997
Start-Up Instructions
3-5
Table 2: Parameter List, Factory (Initial) Settings
Parameter
Value
Description
*
551
0.0
ANALOG OFFSET #1
553
0.0
DIGITAL OFFSET #1
*
558
1500
DANCER FULL POSITION
*
559
750
DANCER MID-POSITON
*
561
131
PRESS REF PPR
*
562
2566
MAX PRESS REF RPM
563
400
VELOCITY KI LOW
564
1700
VELOCITY KI HIGH
565
150
VELOCITY KP LOW
566
425
VELOCITY KP HIGH
567
50
PROCESS REG KI
*
569
30
VP KI/KP SWITCH RPM
*
570
-20
LOW SUM RRDH
571
0
LOW SUM NORMAL
600
625
VEL INDIRECT 1 (P.163)
601
721
VEL INDIRECT 2 (P.164)
602
659
VEL INDIRECT 3 (P.165)
603
660
VEL INDIRECT 4 (P.166)
606
1750
BASE MOTOR SPEED
*
607
-20
REVERSE SPEED LIMIT
*
608
1560
FORWARD SPEED LIMIT BELT
MOTOR RPM PER CHART
609
210
ENCODER PPR
610
500
RATED MOTOR VOLTAGE
611
20.6
MOTOR ARMATURE FLA
612
1.2
RATED FIELD MOTOR CURRENT
613
6
MOTOR INERTIA
614
5.78
ARMATURE RESISTANCE
615
40
RATED ARMATURE BRIDGE
CURRENT
616
2.1
RATED FIELD BRIDGE CURRENT
617
460
RATED AC LINE VOLTAGE
621
0
FEEDBACK DEVICE TYPE
628
1
PROCESS TRIM SELECT
*
633
20
PRESET SPEED 1
*
634
-20
PRESET SPEED 2
635
0
PRESET SPEED 3