Rockwell Automation 873M Ultrasonic Analog Sensors Installation Instructions User Manual

Models covered: indicator led dimensions [mm (in.), Straight model right angle model

Advertising
background image

Installation Instructions

Ultrasonic Analog Sensors

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

Specifications

General

300 mm Models

800 mm Models

Sensing range [mm (in.)]

30…300
(1.18…11.81)

50…800
(1.96…31.49)

Adjustment range [mm (in.)] 50…300

(1.96…11.81)

70…800
(2.75…31.49)

Blind zone [mm (in.)]

0…30 (0…1.18)

0…50 (0…0.96)

Standard target [mm (in.)]

100 x 100 (3.93 x 3.93)

Frequency

Approx. 390 kHz

Approx. 255 kHz

Response delay

Approx. 30 ms

Approx. 100 ms

Operating temperature
[C (F)]

-25…70° (-13…158°)

Storage temperature [C (F)]

-40…85° (-40…185°)

Electrical

Operating voltage

10…30V DC (analog voltage models are
15…30V DC)

Output current

200 mA

Current consumption

<20 mA

Protection type

Short-circuit, reverse polarity, overload

Output

Output type

Analog: 4…20 mA/0…10V DC
depending on model*

Resolution

0.4 mm at max. sensing range

Repeat accuracy

±0.5% of full-scale value

Sensitivity adjustment

Remote teach/optional programming
cable

Environmental

Enclosure type rating

IP67

Shock

30 g, 11 ms

Housing material

Brass, nickel-plated

Connection

Micro-quick disconnect

Certifications

cULus listed and CE marked for all
applicable directives

ATTENTION

If a hazardous condition can result from
unintended operation of this device, access to
the sensing area should be guarded.

Models covered:

Indicator LED

Dimensions [mm (in.)]

873M-D18AI300-D4
Analog current

873M-D18RAI300-D4
Right angle, analog current

873M-D18AI800-D4
Analog current

873M-D18RAI800-D4
Right angle, analog current

873M-D18AV300-D4
Analog voltage

873M-D18RAV300-D4
Right angle, analog voltage

873M-D18AV800-D4
Analog voltage

873M-D18RAV800-D4
Right angle, analog voltage

Operating Mode

Red LED

Yellow LED

Green LED

Teach Mode

Target detected

One flash

Continuous
flash

Off

No target detected

Flashes

Off

Target marginal (invalid teach)

Standard Mode

Target present

Off

On

On

Target not present

Off

Solid-state devices can be susceptible to radio
frequency (RF) interference depending on the
power and the frequency of the transmitting
source. If RF transmitting equipment is to be
used in the vicinity of the solid-state devices,
thorough testing should be performed to
assure that transmitter operation is restricted
to a safe operating distance from the sensor
equipment and its wiring.

IMPORTANT

M12X1

M18X1

LED

M12X1

LED

4

(0.16)
24.5 (0.96)

39.2 (1.54)

67.7 (2.66)

10

(0.39)

10

(0.39)

67 (26.6)

39.2 (1.54)

24.5

(0.96)

Straight Model

Right Angle Model