Volt trim% ref – Rockwell Automation 1336F PLUS II Custom Firmware Inst. - EN916 User Manual

Page 3

Advertising
background image

EN916 - Variable Voltage Control

3

Voltage Control

[Volt Trim% Ref]

This parameter specifies the voltage command trim% val-
ue added/subtracted to [Volt Preset] when [Volt Select] is
set to “Pre+TrimRef”. The trim value is

±

Volt Trim% of

[Rated Voltage].

Minimum Input = –Volt Trim% Value
Mid-Point Input = No Trim
Maximum Input = +Volt Trim% Value

The parameter value is cleared at power-up and is not
retained in eeprom storage. This parameter is intended to
be used with a SCANport communications adapter via the
[Data In xx] Adapter I/O parameters.

Parameter Number

341

Parameter Type

Read and Write

Display Units / Drive Units

1% / 4096 = 100%

Factory Default

0%

Minimum Value

0%

Maximum Value

+100%

Advertising