Troubleshooting Your System

Chapter 5

5Ć3

Symptom

Probable Cause

Recommended Action

Improper interaction

between 1770-M11 system

and the 1775-GA

modules.

1770-CD twinaxle cable not connected.

Twinaxial cable is not properly wired.

Peripheral communication module's

remote channel is not configured for disk

operations.

Two or more 1775-GA modules

connected with twinaxial cable have

identical unit numbers.

Baud rate is not set properly.

You did not enter the proper logical unit

address.

PLC-3 processor system or peripheral

communication module failed.

1770-M10 system address switch is not

properly set.

Micro-floppy is not properly seated into

the disk drive.

Connect the twinaxial cable.

Refer to chapter 3 for proper wiring instructions.

Reconfigure the remote channel through LIST.

Renumber the 1775-GA module.

Set baud rate for 1770-M11 system; then press

the RESTART pushbutton.

Set baud rate for 1775-GA module.

Check your last entry on the CRT screen to verify

the logical unit address.

Troubleshoot the PLC-3 system.

Set internal switch assembly for the 1770=M10

system. Refer to chapter 3.

Eject micro-floppy and re-insert.