3. Mount the base using #8 (M4) screws.
4. Ground the system using the ground lug connection. (The
ground lug connection is also a mounting hole.)
Install the ArmorPoint
Relay Output Module
To install the ArmorPoint relay output module, proceed as follows.
1. Using a bladed screwdriver, rotate the keyswitch on the
mounting base clockwise until the number 7 aligns with the
notch in the base.
2. Position the module vertically above the mounting base. The
module will bridge two bases.
Ground lug connection
Latching mechanism
Keyswitch-
Set to position 7 for
the 1738 Relay
output modules
Mounting base
43675
MOD
NET
1738-OW4M12/A
Form A
Isolated Relay Out
0
1
2
3
0
1
2
3
Module will bridge two bases.
43779