Programming Error Codes
Publication 1771-6.5.126 – March 1998
Type
Example
Description
2
222
Outside fixed limits
02
0222
MCC22 is out of range. Valid range is 00000
≤
MCC22
≤
00099.
3
Cannot be equal
03
0311
MCC11 is equal to MCC12. They must not be equal.
Outside range established by another entry
04
0427
MCC27 is out of range.
If MCC28 is non-zero, MCC27 must be within
MCC23
≤
MCC27
≤
MCC28.
If MCC28 is zero, MCC27 must be within
MCC23
≤
MCC27
≤
MCC24.
5
5 2
Bit selection error
05
0502
MCC02-B04=1 and/or MCC02-B05=1 are illegal configurations.
Block-related configuration error
06
0600
Your entire IPC block has been rejected because the QI module
does not have a valid MCC block on-board (SYS15-B07 = 0)
7
712
Required non-zero entry
07
0712
IPC12 cannot be zero when IPC14 > 00000.
8
816
Entry must be zero
08
0816
IPC16 must be 00000 when IPC12 = 00000.
Entry combination error (group is outside fixed limits)
09
0960
Your entry combination is illegal:
IPC60 = IPC61 = IPC62 = IPC63 = 00000.
Error in entry order
10
1015
IPC is not in decreasing positional order.
If non-zero, IPC15 must be less than IPC11.