Output image – Rockwell Automation 1746-BLM Blow Molding Module Installation Instructions User Manual
Page 32

32 Blow-molding Module
Publication 1746-IN014B-EN-P - January 2001
Output Image
Note:
For description definitions, see page 43.
Addresses for axes 1-4
axis 1
axis 2
axis 3
axis 4
Control-bit Description (1 = enable)
0/0
2/0
4/0
6/0
profile-enable
0/1
2/1
4/1
6/1
hold-value-0
0/2
2/2
4/2
6/2
hold-value-1
0/3
2/3
4/3
6/3
hold-value-2
0/4
2/4
4/4
6/4
download axis control structure (from SLC)
0/5
2/5
4/5
6/5
upload axis control structure (to SLC)
0/6
2/6
4/6
6/6
record current axis position as zero-scale calibration
0/7
2/7
4/7
6/7
record current axis position as full-scale calibration
0/8
2/8
4/8
6/8
download setpoint profile (from SLC)
0/9
2/9
4/9
6/9
upload process-variable profile (to SLC)
0/10
2/10
4/10
6/10
download master setpoint profile (from SLC)
0/11
2/11
4/11
6/11
upload interpolated setpoint profile (to SLC)
0/12
2/12
4/12
6/12
synch input
0/13
2/13
4/13
6/13
synch output
0/14
2/14
4/14
6/14
parison weight control
0/15
2/15
4/15
6/15
accumulator velocity control
1
3
5
7
reserved
8
11
14
17
hold-value “0”
9
12
15
18
hold-value “1”
10
13
16
19
hold-value “2”
20
high speed analog input word (see page 12)
21 – 31
reserved