Environmental Specifications - 1784-U2DN
Attribute
1784-U2DN
Temperature, operating
• IEC 60068-2-1 (Test Ad, Operating Cold)
• IEC 60068-2-2 (Test Bd, Operating Dry Heat)
• IEC 60068-2-14 (Test Nb, Operating Thermal
Shock)
0…55 °C (32…131 °F)
Temperature, nonoperating
• IEC 60068-2-1
(Test Ab, Unpackaged Nonoperating Cold)
• IEC 60068-2-2
(Test Bb, Unpackaged Nonoperating Dry Heat)
• IEC 60068-2-14
(Test Na, Unpackaged Nonoperating Thermal
Shock)
-10…85 °C (14…185 °F)
Relative humidity
IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
5…95% noncondensing
Shock, nonoperating
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
1000 mm (3.28 ft)
Emissions
CISPR 11
Group 1, Class A
ESD immunity
IEC 61000-4-2
8 kV air discharges
Radiated RF immunity
IEC 61000-4-3
• 10V/m with 1 kHz sine-wave
80%AM from 80…2000 MHz
• 10V/m with 200 Hz 50% Pulse
100%AM at 900 MHz
• 10V/m with 200 Hz 50% Pulse
100%AM at 1890 MHz
• 3V/m with 1 kHz sine-wave
80%AM from 2000…2700 MHz
EFT/B immunity
IEC 61000-4-4
±2 kV at 5 kHz on DeviceNet port
Surge transient immunity
IEC 61000-4-5
±2 kV line-earth (CM) on DeviceNet
port
Conducted RF immunity
IEC 61000-4-6
10V rms with 1 kHz sine-wave
80% AM from 150 kHz…80 MHz on
DeviceNet port