Connect the program storage device – Rockwell Automation 1747-PSD Program Storage Device Installation Instructions User Manual
Page 6

6 Program Storage Device
Publication 1747-IN001C-EN-P - May 2006
A 9V dc, Class 2 power supply adapter (120V ac), catalog number 1787-USADPTR,
is available for use with the program storage device.
The adapter plugs into the power supply connection at the top of the module.
For permanent installations, use a power supply adapter.
Connect the Program Storage Device
Connect the program storage device to the controllers with the appropriate cable.
Program Storage Device Connected to Controllers
1747-PSD Cable Connection
Controller
Serial Port
With Cable
(1)
(1)
The cables are not supplied with the program storage device.
SLC 5/03, SLC 5/04, and SLC 5/05
Channel 0 RS-232
1747-CP3
MicroLogix 1000, 1100, 1200, and
1500
1761-CBL-PM02
MicroLogix 1500
Channel 1 RS-232
1747-CP3
MicroLogix 1200
PROG/HMI RS-232
1761-CBL-PM02
Industrial Programming Station
COM1 or COM2
1747-CP3
1747-PSD Programming Device
FROM PLC
MODE
TO PLC
OFF
1747-PSD
Program Storage Device
RUN
PROG
FROM PLC
MODE
TO PLC
OFF
1747-PSD
Program Storage Device
RUN
PROG
1747-CP3 Cable
1747-PSD Programming Device
1761-CBL-PM02 Cable
MicroLogix Controller
SLC Controller