Assemble the wire contacts – Rockwell Automation 1762-OB32T MicroLogix Solid State 24V DC Source Output User Manual
Page 15

MicroLogix 1762-OB32T Solid State 24V DC Source Output Module 15
Publication 1762-IN020B-EN-P - June 2013
Assemble the Wire Contacts
1. Strip the wire insulation to expose 4 mm (5/32 in.) of wire. Crimp pins can accept
22...26 AWG wire.
2. Insert the wire into the crimp pin as far as the wire stop.
3. Crimp the wire barrel around the wire using small needle nose pliers.
4. Crimp the insulation barrel around the wire insulation using small needle nose pliers.
5. Solder wire and wire barrel together using lead-free solder and soldering pencil.
6. Insert the assembled wire contact into the terminal socket. Push the wire contact in until
the tang latches. Make sure the tang is properly latched by lightly pulling on the wire.
ATTENTION
Be careful when stripping wires. Wire fragments that fall into the module could
cause damage. Once wiring is complete, be sure the module is free of all metal
fragments before removing the protective debris strip. Failure to remove the
strip before operating can cause overheating.
4 mm
(5/32 in.)
44916
Wire stop
Wire barrel
Tang
Stripped wire
44921
Insulation barrel
Stripped wire
Tang
44922
Terminal connector
Terminal sockets
Wire contact