Troubleshoot with the Indicators
This module has the following indicators:
•
Network and Module status indicator
•
Logic status indicator
•
Auxiliary Power indicator
•
Individual I/O status indicators for inputs 0 through 3 and
outputs 0 through 3.
The following table describes network and module status indicators.
Net/Mod Status Indicator
Indicator
Status
Off
No power or auto bauding
Flashing Green/Off
On line but not connected
Solid Green
On line, link OK, connected
Flashing Red
Recoverable fault - module configuration error
I/O connection fault - one or more I/O connections in the timed-out
state