Summary of plc configuration and command rungs, 4ć12 – Rockwell Automation 1771-PM , D17716.5.18 U MNL 1771-PM CLUTCH/BRAKE MOD User Manual
Page 35

PC Ladder Programming
Chapter 4
4Ć12
We summarize the bits in module group 7 used for determining
configuration requirements and enabling operator commands (Figure 4.9).
Figure 4.9
Functions of PLC Configuration and Command Bits
17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00
PLC Command Bits
Output image table word,
Module Group 7, Chassis
A & B
PLC Configuration Bits
Bit
Bit Status
Type of
No:
Function:
Set
Reset
Rung:
01
Stations 3 and 4
Used
Not Used
Unconditioned
02
Motion Detector Feedback
Used
Not Used
Unconditioned
03
Valve Stem Feedback
Used
Not Used
Unconditioned
04
Air Pressure Feedback
Used
Not Used
Unconditioned
05
AC Power Configuration
Ungrounded
Grounded
Unconditioned
06
OnĆTheĆHop
Used
Not Used
Unconditioned
07
StrokeĆandĆaĆhalf or HalfĆstroke
Not Used
Used
Unconditioned
10
Press Enable (PLC Command)
Enabled
Disabled
Conditioned
11
StopĆOnĆTop (PLC Command)
Enabled
Disabled
Conditioned
12
Latched Messages (PLC Command)
Enabled
Disabled
Conditioned
13
Lamp Test (PLC Command)
Enabled
Disabled
Conditioned
14
Dump Valve Triacs
Used
Not used
Unconditioned
NOTES: Do not use bits 00 and 15 Ć 17 for any purpose.
See Figure 4.2 for bit addresses
See Figure 4.3 through 4.8 for programming
12254
Summary of PLC Configuration
and Command Rungs