Mounting bracket dimensions – Rockwell Automation 2094 2094 Mounting Bracket Installation Instructions User Manual

Page 2

Advertising
background image

2 2094 Mounting Brackets

Publication 2094-IN008B-EN-P — November 2004

Mounting Bracket Dimensions

Figure 1
Mounting Bracket Dimensions

IMPORTANT

To improve the bond between the brackets and
subpanel, construct your subpanel out of zinc plated
(paint-free) steel. For more information on bonding,
panel layout, and mounting of your Kinetix 6000 drive
system, refer to the Kinetix 6000 Multi-Axis Servo Drive
Installation Manua
l (publication 2094-IN001x-EN-P).

Ø 7.9 (0.31) TYP.

12.7
(0.50) TYP.

Ø 15.9 (0.62) TYP.

M6 x 1 holes

(6 Locations)

76.2
(3.0)

LIM

PRS

PR

LIM

PR/PRS

356 ±0.5

(14.03 ±0.020)

301 ±0.5

(11.86 ±0.020)

401 ±0.5

(15.79 ±0.020)

4.2
(0.16) REF

89.3 ±0.5

(3.51 ±0.020)

40.6
(1.60)

Ground

Stud

23.4
(0.92)

55.3

(2.18)

REF

Dimensions are in millimeters (inches)