Step 3: program the plc – Rockwell Automation 2711E-ND1 PanelBuilder 1400E Reference Manual User Manual
Page 138

133
Scrolling Lists
Publication 2711E-820 – January 1998
The following table displays the addresses for each of the additional
buttons:
Additional Buttons
Command BLK
Transfer Address
Indicator State
BLK Transfer
Address
PLC Address
AUTO MODE
BI52/1 (Value = 1)
N30:3/1 (Value = 1)
MANUAL MODE
BI52/1 (Value = 0)
N30:3/1 (Value = 0)
TOGGLE
COMMAND
BI52/3
N30:3/3
BI52/1
N30:3/1
SET COMMAND
BI52/0
N30:3/0
BI52/1
N30:3/1
MANUAL ON
BI52/4
N30:3/4
BI52/1
N30:3/1
MANUAL OFF
BI52/5
N30:3/5
BI52/1
N30:3/1
NUMERIC KEYPAD
ENTER KEY FOR
STYLE NUMBER
BI52/6
N30:3/6
CHANGE STYLE
NO. CONTROL
ADDR
BI53/0 — 3/15
N30:4
The following table displays the addresses for the Object List PLC
files:
Object List PLC Files
PLC File Addresses
PLC File Data Presets
ASSEMBLY STATION
N31:1 through N31:57
1 through 57
LUXURY OPTION
N32:1 through N32:57
1 through 57
STATION STATUS
N33:1 through N33:57
1
OPTION COMMAND
N34:1 through N34:57
1
OPTION STYLE NO.
N35:1 through N35:57
100
When you have assigned all the addresses for the Object List PLC
files, you are ready to begin programming the PLC.
Step 3: Program the PLC
To program the PLC, follow the ladder diagrams shown in the
following pages.