Rockwell Automation 2090-UXBB-DM15 CN2 Motor Feedback Breakout Board User Manual
Motor feedback breakout board, Installation instructions, Install the motor feedback breakout board

Installation Instructions
Motor Feedback Breakout Board
Catalog Number
2090-UXBB-DM15
Install the Motor Feedback Breakout Board
Refer to the Kinetix Motion Control Selection Guide, publication
information about the compatability of the breakout board with your drive.
Attribute
2090-UXBB-DM15
Cable diameter
11.4 mm (0.45 in.) max
Screw terminal wire size
0.06…1.31 mm
2
(30…16 AWG)
Recommended wire strip length
25…51 mm (1…2 in.)
Recommended torque
Mounting screw
Terminal screw
0.40 N•m (3.5 lb•in)
0.25 N•m (2.2 lb•in)
Locking Tab
Cable Tie
Mounting Screws (2)
2 x 4-40 UNC
Follow these steps to form a compact connection.
1. Push the insulation down-and-over itself.
2. Move the insulation so it butts against the
outside wall of cover.
3. Tape or shrink-wrap the end of the insulation to
the cable.
Shrink-wrapped
Insulation
Cable
Tie
Position cable shield against
this termination pad.
Cable
Shield