4
90A Field SCR Module Replacement (for 1250, 1650, and 3000A 1395 DC Drives)
5.
Disconnect the gate leads from the SCR modules.
6.
Disconnect the busbar connections from the left SCR module by 
removing the three mounting screws.
7.
Remove the two screws which mount the left SCR module and 
take the module out.
8.
Mount the new SCR module by securing the two mounting 
screws (the gate lead prongs should be to the front). Torque to 
45 lb-in.
9.
Secure the busbars to the left module with the three mounting 
screws. Torque to 26 lb-in.