Instance 102 - configuration input / output – Rockwell Automation 1799ER-IQ10XOQ10 Dual-Port EtherNet Embedded I/O Board with 10 Inputs/ Outputs User Manual

Page 15

Advertising
background image

Dual-Port EtherNet Embedded I/O Board with 10 Inputs/ 10 Outputs 15

Publication 1799ER-IN001B-EN-P - May 2013

Refer to the Data Definitions tables for more information.

1799ER-IQ10XOQ10 Data Definitions

Instance 120 - Produced 10 Point Logix Input

Produced
Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Reserved (must be 0)

1

Reserved (must be 0)

2

Reserved (must be 0)

3

Reserved (must be 0)

4

In7

In6

In5

In4

In3

In2

In1

In0

5

Reserved

In9

In8

Instance 126 - Produced 10 Point Input

Produced
Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

In7

In6

In5

In4

In3

In2

In1

In0

1

Reserved

In9

In8

Instance 160 - Consumed 10 Point Output

Consumed
Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Out7

Out6

Out5

Out4

Out3

Out2

Out1

Out0

1

Reserved

Out9

Out8

Instance 102 - Configuration Input / Output

Config Byte Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Reserved CRN

1

Reserved

2

Reserved

3

Reserved

4

Group 0 Input OFF_ON Delay Filter (Low Byte)

Advertising