54 PanelView Plus CE-Specific Extensions to the WinCE API
Return Values:
Remarks:
This function provides “one-shot” behavior. The application must
restart the timer if “periodic” behavior is desired. See
UserTimerSetEx() below.
Any count in progress is aborted by this function.
USER_TIMER_SET_FAILED indicates that the count may be beyond
the hardware capabilities of the timers and may be out of range, or
the frequency had not been set.
Portability:
This function is specific to the PanelView Plus CE or the RAC6182.
Requirements:
UserTimerSetEx
This function sets the count of a claimed timer and start timing the
countdown.
DWORD UserTImerSetEx (DWORD dwTimerNumber, DWORD
dwCount, DWORD dwMode)
UserTimerSet - Return Codes
Value
Description
USER_TIMER_OK
The countdown was set and the timer started.
USER_TIMER_INVALID_TIMER
The timer number is not valid for the system.
USER_TIMER_INVALID_PARAMETER
dwCount was 0.
USER_TIMER_NOT_CLAIMED
This application has not claimed this timer.
USER_TIMER_SET_FAILED
Unable to set countdown value.
Runs On
Version
Defined In
Link To
PanelView Plus CE
RAC6182
All
usertimers.h
usertimers.lib