6 Kinetix 6000M IPIM-to-IDM Hybrid Cable

Publication 2090-IN031B-EN-P - March 2012

5. Tighten the M23 connector approximately 45° to fully seat the contacts and secure the

connection.

2090-CHBIFS8-12AA Cable Schematic and Connector Pinout

IMPORTANT

The internal O-ring is self-conforming and requires a short period between each
connect/disconnect cycle to expand to full size. Let the O-ring expand for at least 60 seconds
before reconnecting a hybrid cable.

A

B

GND

C

D

4
5
6

7
8

9

10

IPIM Terminals

DC+

DC-

42+

42-

SE1

SE-

SE2

SH3

CN-

CN+

SH2

OUT

RTN

(1)

(2)

(2)

(3)

(3)

(1)

Brown

Grey

Blue

White/Blue

Brown

White/Pink

Pink

Green/Yellow

Orange

Violet

Yellow

Braided Shield

Twisted pair

Shield

Wire Connection

1. The braided shield connects to the cable ground clamp with a 360º connection.
2. Drain wire provides continuity from the connector to the cable ground clamp.
3. Braided shield provides continuity from the connector to the cable ground clamp.

White/Brown

GND

7

8

9 10

6

5

4

1

3

2

D

A

B

C

Female Plug