Rockwell Automation 2711-NL1 PanelView 550 Backlight Lamp Replacement User Manual

Page 3

Advertising
background image

40061-182-01(C)

3

To replace the backlight lamp:

1. Turn off the power to the PanelView terminal.

Important: Turning off the power provides a standard reset. Changing the
lamp with power applied may result in an unintentional reset.

2. Remove lamp access cover.

3. Disconnect backlight lamp cable connector. The connector has a locking tab

which you must press to separate the connector.

4. Remove lamp from mounting clip. Avoid contact with the infrared filter.

5. If your terminal has a metal lamp clip (see illustration on previous page), you

will need to replace it with the new lamp base provided in this kit. Replace the
lamp base by removing the two screws that secure the lamp base and re-install
the new base.

6. Insert the new lamp into holder.

7. Connect lamp cable to connector. Make sure that cable is firmly held and in the

proper position.

8. Replace lamp access cover.

9. Apply power to the terminal.

10. If new lamp does not illuminate, refer to the PanelView Operator Terminal User

Manual for instructions on lamp control from the front panel.

Access Cover

PanelView 550

Touch & Keypad, Keypad Only versions

PanelView 550

Touch Only Versions

Access Cover

!

ATTENTION: Lamp may be hot. Allow lamp to cool before
proceeding to avoid personal injury.

!

ATTENTION: Do not touch the reflecting surface or halogen
bulb when handling new lamp to avoid damaging lamp.