Rockwell Automation 1797-BCNR FLEX Ex Redundant ControlNet Barrier Module User Manual
Page 13

FLEX Ex Redundant ControlNet Barrier Module 13
Publication
1797-5.35 - July 2004
1797-BCNR Specifications
Conducted RF Immunity
IEC 61000-4-6:
10Vrms with 1kHz sine-wave 80%AM from 150kHz to
80MHz
Enclosure Type Rating
None (open-style)
Certifications
1
(When Product is Marked)
CENELEC
DMT 99 ATEX EO65 X
II (2) G[EEx ib] IIC
II 3G EEx nA IIC T4 X
CE
European Union 89/336/EEC EMC
Directive, compliant with:
EN 61326; Meas./Control/Lab.,
Industrial Requirements
EN 61000-6-4; Industrial
Emissions
EN 61000-6-2; Industrial Immunity
cULus
Provides intrinsically safe outputs for use in
Class I, Division 1, Groups A, B, C, and D;
Class II, Groups E, F, and G; Class III;
Class 1, Zone 1 Group IIC
C-Tick
Australian Radiocommunications
Act, compliant with:
AS/NZS CISPR 11; Industrial
Emissions
EEx
European Union 94/9/EEC ATEX
Directive, compliant with:
EN 50014; Potentially Explosive
Atmospheres General
Requirements
EN 50020; Potentially Explosive
Atmospheres, Protection “i”
EN 50021; Potentially Explosive Atmospheres,
Protection "n" (Zone 2)
1. See the Product Certification link at www.ab.com for Declarations of Conformity,
Certificates, and other certification details.