User Interface

Using an instrument screwdriver, open the top cover of the sensor to gain access to the

user interface panel. This panel contains a pushbutton and LED indicators for

configuring and viewing the sensor’s operation and status. A more complete description

of each item is described below.

Timing Sensors—Top View Detail

Red/Green Status

Green -- Margin

Yellow -- Output

Sensitivity Adjustment

Programming

Pushbutton

Pushbutton

A single momentary pushbutton is used to configure the sensor (strobing models only).

Refer to the configuration section in this document for complete instructions on using

this feature.

LED Indicators

Three LED indicators are provided to indicate a variety of conditions making it easy for

installation and troubleshooting. The function of each is described in the table below.

The LEDs also work together as indicated on page 5 when used in the configuration

mode.

Table 1. LED Function

Label

Color

State

Status

Output

Yellow

ON

Target detected

Margin

Green

OFF

Margin < 2.5

ON

Margin >2.5

Status

Red/Green

OFF

Sensor not powered

Green ON Steady

Sensor active and allocated by master

Green Flashing

Sensor active but not allocated by master

Red Flashing

Minor correctable fault (baud rate)

Red ON Steady

Major fault (possible duplicate address)

NOTE

: LED indicators are used during the configuration operation of the sensor. Refer to the configuration section for

complete instructions on using this feature.

Mounting the Sensor

Securely mount the sensor on a firm, stable, surface or support using one of the many

mounting brackets available from Rockwell Automation/Allen-Bradley. The sensor is

supplied with hardware kit #129--130 which contains a plastic mounting nut, lock

washer, 2 M5 x 0.8 x 53 screws and nuts. Excessive vibration or shifting may cause

intermittent operation of the sensor.

M5 x 0.8 x 53

Combination

Screws and Nuts

(Supplied)

Hardware Kit

(Supplied)

Wiring the Sensor

Models of the Series 9000 DeviceNet are available in one of three different connection

types as identified in the following table. Rockwell Automation/Allen-Bradley

recommends the use of the 1485R Series of cordsets and patchcords on the

quick-disconnect models. All external wiring should conform to the National Electric

Code and all applicable local codes.

Designation

Lead Color

Pin Assignment

2m Cable

5-Pin Micro QD

5-Pin Mini QD

1

3

2

4

5

1

3

2

4

5

V+

Red

2

2

V--

Black

3

3

CAN +

White

4

4

CAN --

Blue

5

5

Drain

Bare

1

1

Advertising