Rockwell Automation 5000 On-Off Background Suppression Control Type 42MBS User Manual

Installation instructions photoswitch

Advertising
background image

INSTALLATION INSTRUCTIONS PHOTOSWITCH

ON-OFF BACKGROUND SUPPRESSION CONTROL, BULLETIN 42MBS-5000

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE. FOR ADDITIONAL INFORMATION REFER TO PUBLICATION PG-9000

BULLETIN NUMBER

OPERAT-

ING

MODE

VOLTAGE SUPPLY

POWER

CON-

SUMP-

TION

OUTPUT CHARACTERISTIC

RESPONSE TIME

(ADD FOR TOTAL)

SUPPRES-

SION POINT

ADJUST-

MENT

RANGE

TYPICAL SUPPRESSION

QUALITY

PHOTOHEAD

POWERBASES

OUTPUT

MODULE

TYPE

RATING

LEAKAGE

(OFF

STATE)

CON-

TROL

OUTPUT

WHITE

BACK-

GROUND

CONTROL

OFF

BLACK

TARGET

CONTROL

ON

42MBS-5000

ON-OFF

5ms

2.5--1.2

(6.35cm--

30.5cm)

2.5

(6.35cm)

4

(10.1cm)

6

(15.2cm)

8

(20.3cm)

10

(25.4cm)

12

(30.5cm)

2.3

(5.89cm)

3.9

(9.9cm)

5.8

(14.7cm)

7.7

(19.5cm)

9.5

(24.1cm)

10.5

(26.6cm)

42MTB-5000

102--132 VAC

2VA

42MTB-5001

204--254 VAC

4VA

42MTB-5002

40--54 VAC/DC

1VA

42MTB-5003

20--30 VAC

1VA

42MTB-5004

20--30 VDC

1VA

8-590 &

8-594

*

SPDT

EM

RELAY

2A--120 VAC

1A--240 VAC

10ms ON

15ms

OFF

8-591

SP--NO

AC/DC

FET

30mA

0--120V

AC/DC

10A

1ms

8-592

SP--NO

AC

TRIAC

.75A

240 VAC

1mA

8ms

8-593

*

NPN

& PNP

100mA

30 VDC

1A

1ms

*

Use with 42MTB-5004 base ONLY. Other output modules will not function with 5004 base.

SPECIFICATIONS:
Range Adjustment

Fine and Coarse

. . . . . . . . . . . . . . . . . . . . . . . .

Ambient Temperature Range

For E--M Relays

--40

o

F to 150

o

F (--40

o

C to 65

o

C)

. . . . . . . . . . . .

For S.S. Relays

--40

o

F to 125

o

F (--40

o

C to 52

o

C)

. . . . . . . . . . . . .

Relative Humidity

90%

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Turn on Pulse Suppression

Yes

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Field of View

3

o

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Light and Dark Operation

Selectable by switch on photohead

. .

Operating Environment: NEMA 3, 4, 12, 13, and IP66 (IEC529)
Approvals

UL Listed and CSA Certified

. . . . . . . . . . . . . . . . . . . .

Lens Material

Acrylic

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Transmitting LED

Infrared 880nm

. . . . . . . . . . . . . . . . . . . . . . . .

Housing Material

High impact chemically resistant Valox

. . . . .

Margin and Alignment Indicator

-- Red

Output Energized

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-- Green

2 X Margin

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Termination

Supplied with #6/32 nickel plated brass

. . . . . . . . . .

pressure type materials

ACCESSORIES
Optional Mounting Assemblies

PART NUMBER

DESCRIPTION

60-1785

Universal Mounting Assembly

60-1748

Heavy Duty Mounting Assembly

60-1840

Right Angle Mirror

60-2014

Flexi-mount Mounting Assembly

60-2072

PHOTOcountSWITCH Totalizer

60-2083

Photoguard Heavy Duty Protection

60-2213

Conduit Mounting Adapter

60-2230

Limit Switch Type Mounting Assembly

61-5540

Nema 7 and 9 Enclosure

Advertising