Install the control interface breakout board – Rockwell Automation 2090-U3CBB-DM12 CN1 Control Interface with Integral 24V-to-5V Power Installation Instructions User Manual

Page 2

Advertising
background image

2 Control Interface Breakout Boards with 24V-to-5.2V Auxiliary Power Converter

Rockwell Automation Publication 2090-IN008B-EN-P - August 2010

Install the Control Interface Breakout Board

Attribute

2090-U3CBB-DM44, 2090-U3CBB-DM12

Cable diameter

12.7 mm (0.5 in.) max

Screw terminal wire size

0.06…1.31 mm

2

(30…16 AWG)

Recommended wire strip length

25…63 mm (1.0…2.5 in.)

Auxiliary power input

Voltage
Current

18…30V DC
400 mA max

Recommended torque

Mounting screws
Terminal screws

0.40 N•m (3.5 lb•in)
0.25 N•m (2.2 lb•in)

1 X- X+ 4 5 6 7 8 9

16 17 18 19 20 21 22 23 24

25 26 27 29 31 32 33 34 35

36 37 38 39 40 41 42 43 44

AUXPWR

AUXCOM

ENABLE

HOME

REG1

REG2

OTRAV+

OTRAV-

I/OCOM

BRAKE+

BRAKE-

SHIELD

CN1-31

CN1-32

CN1-33

CN1-34

CN1-37

CN1-38

CN1-27

CN1-43

CN1-44

Cable Tie

Follow these steps to form a compact connection.
1. Push the insulation down-and-over itself.
2. Move the insulation so it butts against the outside wall of cover.
3. Tape or shrink-wrap the end of the insulation to the cable.

Shrink-wrapped Insulation

44-pin Breakout Board

12-pin Breakout Board

Advertising