Section 2

Installation of an Enclosed System Multiplexer / Permissive Module

To install a factory or customer enclosed System Multiplexer / Permissive Module, perform the following steps:

1. Determine a suitable location for mounting the System Multiplexer / Permissive Module enclosure.

2. Based on the enclosure selected, locate and mark the necessary mounting bolt hole locations on the mounting surface. Drill and tap as needed
for mounting bolts suitable for the support of the enclosed System Multiplexer / Permissive Module.

IMPORTANT: Before mounting an enclosed System Multiplexer / Permissive Module and based upon installation requirements, the openings for conduit or cable
fittings should be made to the enclosure.
If enclosure is customer supplied, conduit or cable fitting openings should be made before installing the open style System Multiplexer / Permissive Module in the
enclosure. This should be done to avoid contaminating the module with fabricating debris.
If enclosure is factory supplied, the System Multiplexer / Permissive Module should be removed from the enclosure, prior to making any openings for conduit or
cable fittings, to help avoid module contamination (see Section 1 for instructions on removing the System Multiplexer / Permissive Module from an enclosure).

3. Support the enclosure while aligning it with the mounting bolt holes.

4. Install enclosure mounting bolts and tighten to torque required for mounting bolt size selected.

5. Mount the System Multiplexer / Permissive Module inside the enclosure (see Section 1 for instructions on installing the System Multiplexer /
Permissive in an enclosure).

6. Select which System Multiplexer / Permissive Module connector plugs will require wiring (see Table 1 and Figures 1 and 3).

Connector

RLS S#_A thru RLS S#__F

System Multiplexer / Permissive Module Remote
Lockout Station

C o n n e c t s R e m o t e L o c k o u t S t a t i o n t o
System Multiplexer / Permissive Module.

EXB1 THRU EXB4

S y s t e m M u l t i p l e x e r / P e r m i s s i v e M o d u l e
Connectors to ElectroGuard® Systems (See
Section 3)

Permissive inputs from the PLC and safety relay
output status

The permissive input allows the machine
controlling the process or drive system to
b r i n g t h e m a c h i n o r p r o c e s s t o a
predetermined stopping point prior to
removal of power by the ElectroGuard®
system. Output terminals provide the
status of safety relays SR1 and SR7.

PLC1EXB

PER1

Remote Lockout Station status to customer
remote PLC (See Section 5)

Connects RLS auxiliary signals to Remote
P L C o r o p t i o n a l R e m o t e I / O o r
Communication Modules.

Interconnects the System Multiplexer /
Permissive Module to the Control Modules
in ElectroGuard® Systems, or to series
connected System Multiplexer / Permissive
Module.

Description

Function

(2)

Table 1
System Multiplexer / Permissive Module Connectors

Figure 1
Connectors in
4 Port System Multiplexer /
Permissive Module

RLS_A
RLS_B

RLS_C
RLS_D

RLS_E
RLS_F

EXB1
EXB2

EXB3
EXB4

PLC1EXB
PLC2EXB

PER1
PER2

Figure 2
Keying of RLS Connectors at System Multiplexer / Permissive Module

The connectors at System Multiplexer / Permissive Module are "Keyed" in order to uniquely identify each connector, in the event they are
removed and re-inserted (See Figure 2).

7. Follow the specified System Multiplexer / Permissive Module Connector's section (Table 1) to wire connectors.

SYSTEM MULTIPLEXER / PERMISSIVE MODULE

INSTALLATION INSTRUCTIONS

1

1024403

42052-164

OF

N/A

N/A

N/A

REVISION

AUTHORIZATION

DR.

CHKD.

APPD.

DATE

DATE

DATE

E - DOC

LOCATION: MILWAUKEE, WISCONSIN U.S.A.

B-vertical.ai

DWG.

SIZE

SHEET

B

1

2

3

4

5

6

7

8

A

B

C

D

E

F

G

H

REFERENCE

DIMENSIONS APPLY BEFORE

SURFACE TREATMENT

(DIMENSIONS IN INCHES)

TOLERANCES UNLESS

OTHERWISE SPECIFIED

.XX:

.XXX:

ANGLES:

42052

------------

----------
----------

----------

------------

------------

2

8

THIS DRAWING IS THE PROPERTY OF

ROCKWELL AUTOMATION, INC.

OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,

USED OR DISCLOSED FOR ANY PURPOSE

EXCEPT AS AUTHORIZED IN WRITING BY

ROCKWELL AUTOMATION, INC.

RLS_A

RLS_C

RLS_E

PER1

PLC1 EXB

PLC2 EXB

RLS_B

RLS_D

RLS_F

EXB1

EXB2

EXB3

EXB4

T

1

2

3

4

5

6

7

8

9

G
N
D

10

1

2

3

4

5

6

7

8

9

G
N
D

10

1

2

3

4

5

6

7

8

9

G
N
D

10

1

2

3

4

5

6

7

8

9

G
N
D

10

1

2

3

4

5

6

7

8

9

G
N
D

10

1

2

3

4

5

6

7

8

9

G
N
D

10

1

2

3

4

5

6

7

8

9

G
N
D

10

1

2

3

4

5

6

7

8

9

G
N
D

10

8

1

2

3

4

5

6

7

9

G
N
D

10

PER2

8

1

2

3

4

5

6

7

9

G
N
D

G
N
D

10

8

1

2

3

4

5

6

7

9

10

11

12

8

1

2

3

4

5

6

7

9

10

11

12

1

2

3

4

5

6

7

8

9

G
N
D

10

1

2

3

4

5

6

7

8

9

G
N
D

10

B

P
L
U
G

T

B

P
L
U
G

T

B

P
L
U
G

T

B

P
L
U
G