Rockwell Automation 5000 Red Line User Manual

Installation instructions—photoswitch, Series 5000 red line, Typical response curves

Advertising
background image

1

Installation Instructions—PHOTOSWITCH

R

Series 5000 Red Line

All Sensors

Diffuse/Retroreflective

Polarized Retroreflective

1

Sensing Distance

1.5m (5ft)/6m (20ft)

6m (20ft)

2

Transmitting LED

Infrared 880nm

Visible red 660nm

3

Indicators

Red: Output

4

Field of View

3_

5

Sensitivity Adjustment

Yes

6

Operating Temperature

--40_C to +65_C (--40_F to +150_F) except AC TRIAC outputs: --40_C to +52_C (--40_F to +125_F)

7

Relative Humidity

90% maximum

8

Housing/Lens Material

Valox

/Acrylic

Valox

/Glass

9

Cover Gasket Material

Nitrile

10

Operating Environment

NEMA 3, 4, 12, 13, and IP66 (IEC 529), corrosion resistant, high-impact housing

11

Approvals

UL listed, CSA certified (except cable style power base), and CE marked for all applicable directives

12

Protections

Power on False Pulse protection

13

Vibration

10--55 Hz, 1 mm amplitude, Meets or exceeds IEC 947--5--2

14

Shock

30G, Meets or exceeds IEC 947--5--2

Photohead with EM Relay (SPDT)

15

Catalog Number

42LRC--5000

42LRC--5200

16

Output Energized

LO/DO Selectable

17

Load Current

2A @ 120V AC/1A @ 240V AC

18

Leakage Current

19

Response Time (photohead and output)

15 On

20 Off

Photohead with AC/DC Solid-State FET Output (SP- N.O.)

15

Catalog Number

42LRC--5010

42LRC--5210

16

Output Energized

LO/DO Selectable

17

Load Current

30mA 0--120V AC/DC

18

Leakage Current

10A

19

Response Time (photohead and output)

6ms

Photohead with AC/DC Solid-State TRIAC Output (SP- N.O.)

15

Catalog Number

42LRC--5020

42LRC--5220

16

Output Energized

LO/DO Selectable

17

Load Current

0.75A @ 240V AC

18

Leakage Current

1mA

19

Response Time (photohead and output)

13ms

Base

15

Catalog Number

42LTB--5000 & 42LCB--5000

42LTB--5001

20

Supply Voltage

120V AC

240V AC

21

Power Consumption

2VA

4VA

0.30m

(1)

Retroreflective

Polarized Retroreflective

Standard Diffuse

Operating Distance

O

per

atin

g

M

ar

gi

n

Operating Distance

O

per

atin

g

M

ar

gi

n

Operating Distance

Oper

at

ing

M

ar

gin

4.5m

(15)

100

10

25.4mm

(1)

15m

(50)

0.3

(1)

1m

(3.5)

1000

1

76mm (3I)

Reflector

100

10

1000

1

White Paper

4.5m

(15)

25.4mm

(1)

15m

(50)

0.3

(1)

1m

(3.5)

20

10

8

4

2

1

25.4mm

(1)

15m

(50)

1.5m

(5)

0.60m

(2)

3m

(10)

76.2mm

(3)

76mm (3I)

Reflector

32mm

(1.25I)

Reflector

Typical Response Curves