Install the low-profile endat feedback module – Rockwell Automation 2090-K7CK-KENDAT EnDat Feedback Module Installation Instructions User Manual

Page 2

Advertising
background image

2 Low-profile EnDat Feedback Modules

Rockwell Automation Publication 2090-IN020C-EN-P - August 2010

Install the Low-profile EnDat Feedback Module

Attribute

2090-K6CK-KENDAT, 2090-K7CK-KENDAT

Cable diameter

4…10 mm (0.16…0.39 in.)

Screw terminal wire size

0.06…1.31 mm

2

(30…16 AWG)

Recommended wire strip length

5 mm (0.2 in.) single conductor

Recommended torque

Mounting screw
Terminal screws
Clamp and cover screws

0.4 N•m (3.5 lb•in)
0.2 N•m (2.1 lb•in)
0.4 N•m (3.5 lb•in)

Status indicator lights

Red (flashing)
Green (solid)
Red (solid)

Establishing communication
Communication established
Communication fault

Follow these steps to form a compact connection.
1. Push the insulation down-and-over itself.
2. Move the insulation so it butts against the

outside wall of cover.

3. Tape or shrink-wrap the end of the insulation to

the cable.

Do not extend cable
shield above clamp.

Status Indicator

If necessary, turn clamp over
to hold small wires secure.

Shrink-wrapped
Insulation

Clamp Screws (2)

Advertising