Removing the line rc suppressor pcb – Rockwell Automation 2364,2364E Line RC Suppressor Replacement User Manual
Page 3
Advertising

Line RC Suppressor Replacement
3
Publication 2300-5.13 - April 1998
Removing the Line RC Suppressor
PCB
Use this procedure to remove the line RC suppressor PCB:
1. Remove all Lexan ™ guards that shield the PCB.
2. Remove all power and ground wiring connected to the line RC
suppressor PCB.
3. Snap the PCB from the 6 nylon standoffs that secure the PCB.
(Refer to arrows in figures 1 and 2 for standoff locations.)
4. Remove the line RC suppressor PCB.
Figure 1
AC Line Suppressor for 230, 380, 460, and 575V AC
Figure 2
AC Line Suppressor for 660V AC
L1
L2
L3
COMMON
COMMON
L2
L1
L3