Removing the line rc suppressor pcb – Rockwell Automation 2364,2364E Line RC Suppressor Replacement User Manual

Page 3

Advertising
background image

Line RC Suppressor Replacement

3

Publication 2300-5.13 - April 1998

Removing the Line RC Suppressor
PCB

Use this procedure to remove the line RC suppressor PCB:

1. Remove all Lexan ™ guards that shield the PCB.

2. Remove all power and ground wiring connected to the line RC

suppressor PCB.

3. Snap the PCB from the 6 nylon standoffs that secure the PCB.

(Refer to arrows in figures 1 and 2 for standoff locations.)

4. Remove the line RC suppressor PCB.

Figure 1
AC Line Suppressor for 230, 380, 460, and 575V AC

Figure 2
AC Line Suppressor for 660V AC

L1

L2

L3

COMMON

COMMON

L2

L1

L3

Advertising