Communicate with your module, Ethernet/ip connection with rslogix 5000 – Rockwell Automation 1799-OQ10X Embedded I/O Expansion Board with 10 Outputs User Manual
Page 12

12 Embedded I/O Expansion Board with 10 Outputs
Publication
1799-IN013B-EN-P - May 2013
Communicate with Your Module
EtherNet/IP Connection with RSLogix 5000
The following instructions are for RSLogix 5000 version 17 or later.
1. Power down and connect the expansion board to base board.
2. Power up the board and obtain the IP address via DHCP.
3. In the General tab, click the Change button.
4. In the Module Definition screen, select 1799-OQ10X 10 Point 24V
DC output for the expansion module.
5. Click the OK button, then click the Apply button.
1799-OQ10X + 1799-OQ10X Data Definition (optional)
Instance 161 - Consumed 20 Point Output
Consumed
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Out7
Out6
Out5
Out4
Out3
Out2
Out1
Out0
1
Out15
Out14
Out13
Out12
Out11
Out10
Out9
Out8
2
Reserved
Out19
Out18
Out17
Out16
3
Reserved