Figure 2.4 4 way ebu with follower drive – Rockwell Automation 4100-EF04_EF08 4 or 8 Way Encoder Buffer Unit Installation and Setup Manual User Manual

Page 21

Advertising
background image

Publication 4100-IN054B-EN-P - January 2001

Installation 2-5

ALEC units are also shown connected to other follower outputs
demonstrating that a combination of ALEC modules and follower
drives is permissible.

Figure 2.4 4 Way EBU with Follower Drive

4 Channel Encoder Buffer

+12V +5V

HEALTHY

P1

P2

P3

P4

P5

P6

MASTER

FLWR-1

FLWR-2

FLWR-3

FLWR-4

LK-Volts ENC VOLTAGE

LK-DIR

ENCODER DIRECTION

LK-5V-F1

LK-5V-F2

LK-5V-F3

LK-5V-F4

FOLLOWER POWER LK-5V-FX

24V DC Power

System Control Encoder

4 Channel Encoder Buffer Unit

QUALITY

ALEC

Fuse

Common
24V DC

F

a

ult P

o

w

e

r

Rela

y Input

Registr

ation

Input

Incremental

Encoder Input

Encoder OK

AxisLink

1

2

AxisLink
Address

Mode

AL

CPU OK

Reset

12V/5V
Extd Node On/Off
Enc. Fault On/Off

Extd Length On/Off
Extd Term 1 On/Off
Extd Term 2 On/Off

12

3
4
5
6

QUALITY

ALEC

Fuse

Common
24V DC

F

ault P

o

w

e

r

Rela

y Input

Registr

ation

Input

Incremental

Encoder Input

Encoder OK

AxisLink

1

2

AxisLink
Address

Mode

AL

CPU OK

Reset

12V/5V
Extd Node On/Off
Enc. Fault On/Off

Extd Length On/Off
Extd Term 1 On/Off
Extd Term 2 On/Off

12

3
4
5
6

QUALITY

ALEC

Fuse

Common
24V DC

F

ault P

o

w

e

r

Rela

y Input

Registr

ation

Input

Incremental

Encoder Input

Encoder OK

AxisLink

1

2

AxisLink
Address

Mode

AL

CPU OK

Reset

12V/5V
Extd Node On/Off
Enc. Fault On/Off

Extd Length On/Off
Extd Term 1 On/Off
Extd Term 2 On/Off

12

3
4
5
6

ALEC 1

ALEC 2

ALEC 3

Motor

Follower
Encoder

Power

Follower
Encoder

Master
Encoder

FOLLOWER DRIVE

IMPORTANT

P3 is the only output to which the motor thermal
information and analog position reference are
brought out. Only this output should be used to
complete the encoder feedback loop.

Advertising