Wiring the incremental encoder connections – Rockwell Automation 2098 Kinetix 6000 or Ultra3000 to Gettys XP Incremental Encoder  User Manual

Page 2

Advertising
background image

Publication 2090-IN015A-EN-P - January 2007

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

Wiring the Incremental Encoder Connections

Allen-Bradley, Kinetix, Rockwell Automation, and Ultra3000 are trademarks of Rockwell Automation, Inc.

Trademarks not belonging to Rockwell Automation are the property of their respective companies.

Kinetix 6000 Drive

Gettys Encoder

Ultra3000 Drive

Signal

MF-Pin #

Wire Color

Signal

Notes

Signal

CN2-Pin #

A+

1 White/Green

A+ — A+

1

A- 2 Green/White

A-

A- 2

B+ 3 White/Blue

B+

B+ 3

B- 4 Blue/White

B-

B- 4

Index+ 5

Wht/Orange

Z+

Index+ 5

ECOM 6

Blue/Red Com

ECOM 6

S3 8 Red/Orange

W

S3 8

Index-

10 Orange/White

Z-

Index-

10

S1 12 White/Gray

U

S1 12

S2 13 White/Brown

V

S2 13

EPWR_5V 14

Red/Blue

+Vdc

EPWR_5V 14

Overtemp

(1)

(1)

The Kinetix 6000 and Ultra3000 drives require the use of a Motor Feedback Connector (catalog number 2090-K6CK-D15MF)
with thermal-switch filter terminals to provide Over Temp signal termination. Refer to Wiring the Power Connections on
page 1.

16 Blue Over

Temp

From

Motor

Power cable

TS+

(1)

11

Overtemp

(1)

17 Blue Over

Temp

TS-

(1)

6

— Connector

Shield

Drain
Wire/Shield

— — —

Connector
Shield

Advertising