Rockwell Automation MRB04XM Remote Bus Extender Master Module User Manual
Page 3

MRB04XM October 2005 – Issue 5
3
Triguard SC300E MRB04XM Remote Bus Extender Master Module
SPECIFICATION
Model
MRB04XM
Fibre optic ports
4 transmit, 4 receive
Fibre optic cable (not supplied)
Multimode 62.5/1259m cable & 50/1259m
cable (ST connector to ST connector)
Maximum drive loss
50/1259m cable = 9dB
62.5/1259m cable = 16dB
Indicators
Health, Tx, Rx
Module power consumption
3W
Overall size (mm)
Overall size (inches)
400(9U)H x 397L x 28W
15.75H x 15.63L x 1.1W
Weight
1.0kg
ENVIRONMENTAL SPECIFICATIONS
The maximum ambient temperature measured at the hottest point within the Triguard system
shall not be greater than 60 degrees centigrade.
Temperature operating:
+5°C to +60°C
Temperature storage:
-25°C to +70°C
Humidity
5% to 95% non-condensing at ambient <40°C
Certification:
General Certification: Ref. SC300E TMR Product Guide (ref 008-5209)
TRANSPORT AND HANDLING
The MRB04XM must be transported and stored in its original packing material which should be
retained for this purpose.