Rockwell Automation 2099-BMxx-S Kinetix 7000 Drive Systems Design Guide User Manual
Page 20

20
Rockwell Automation Publication GMC-RM007A-EN-P - September 2011
Kinetix 7000 Drive Systems
Kinetix 7000 (400V class) Drives/MP-Series Low Inertia Motor Curves (continued)
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
0
2000
1000
500
1500
160
0
0
20
177
40
354
60
531
80
708
1416
140
1239
120
1062
100
885
2099-BM06 and MPL-B680D
Torque
(N•m)
Torque
(lb•in)
120
100
80
60
40
20
0
1062
885
708
531
354
177
0
Speed (rpm)
0
2000
3000
1000
500
1500
2500
2099-BM06 and MPL-B680F
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
0
2000
1000
500
1500
160
0
0
20
177
40
354
60
531
80
708
1416
140
1239
120
1062
100
885
2099-BM06 and MPL-B860D
Torque
(N•m)
Torque
(lb•in)
0
2099-BM07 and MPL-B880C
442
885
1328
1770
2213
0
50
100
150
200
250
Speed (rpm)
0
1500
1000
500
1250
750
250
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
0
2000
1000
500
1500
160
0
0
20
177
40
354
60
531
80
708
1416
140
1239
120
1062
100
885
2099-BM07 and MPL-B880D
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
0
300
600
0
900
2099-BM06 and MPL-B960B
1200
442
885
1328
1770
2213
0
0
50
100
150
200
250
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage