Rockwell Automation DC3N DC Drive User Guide, 1/4-2HP-115/230 VAC User Manual
Page 10

Adjustments and Application Data (cont.)
2
Specifications
Speed Range
60:1
Accel. Time Range
0–90 VDC Armature Voltage
0.5–17 seconds
0–180 VDC Armature Voltage
0.5–17 seconds
Decel. Time Range
0-90 VDC Armature Voltage
0.5–17 seconds
0–180 VDC Armature Voltage
0.5–17 seconds
Current Limit Overload Range
150%
Analog Input Voltage Range (must be isolated; S1 to S2)
for 0–90 VDC Armature Voltage
0–1.4 VDC
for 0–180 VDC Armature Voltage
0–2.8 VDC
Torque
150% of rated current
Input Impedance (S1 to S2)
100K ohms
Speed adjust potentiometer rating
10k ohm, 5W (5k ohms acceptable)
IR Drop Compensation (% of rated armature voltage)
0% to 15%
Service Conditions
Elevation
3300 ft (1000 m) max without derating**
Vibration
0.5G max (0–50 Hz)
0.1G max (>50 Hz)
Ambient Temperature Range
Enclosed drive
10°C–40°C
Chassis drive
10°C–55°C
Non-condensing Relative Humidity
0% to 95%
** Derate the current by 1% for every 300 ft (90m) above 3300 ft. (1000m), up to
10,000 ft (3000m)
Safety Certification
UL Listed Component
cUL Listed Component
CE Certificate of Compliance