Loosen the compression coupling bolts – Rockwell Automation RDD-B4102 Rotary Direct Drive Bearingless Motors User Manual

Page 23

Advertising
background image

RDD-Series Rotary Direct Drive Bearingless Motor Installation Instructions 23

Publication RDB-IN002B-EN-P — February 2010

Loosen the Compression Coupling Bolts

Follow these steps to loosen the compression coupling bolts prior to releasing the
compression coupling from the shaft.

1. Access the compression coupling bolts through the holes labelled A.

• The RDB-

x

290

x

motor has six (6) compression bolts to loosen.

• The RDB-

x

410

x

motor has ten (10) compression bolts to loosen.

Refer to the diagram on

page 15

for the locations.

2. Moving in a circular pattern, use a 6 mm hex bit to loosen each compression

coupling bolt.

3. Loosen each bolt two (2) revolutions beyond finger-tight.

WARNING

Loosening the compression coupling bolts more than two (2) rev-
olutions beyond finger-tight may disengage the compression cou-
pling from the rotor.

Advertising