Rockwell Automation DC2-71, 78, 91, and 98 Drive Fuse Kit Options For all DC2 Controllers except User Manual

Page 2

Advertising
background image

2

F2DC2000 Fuse Kit

DANGER

DO NOT INSTALL MODIFICATION KITS WITH POWER APPLIED TO THE UNIT. DISCONNECT AND

LOCK OUT INCOMING POWER BEFORE ATTEMPTING SUCH INSTALLATION. FAILURE TO

OBSERVE THIS PRECAUTION COULD RESULT IN SEVERE BODILY INJURY OR LOSS OF LIFE.

(Refer to Figure 1 for fuse kit connections.)

To Controller

Terminal 51

To Controller Terminal L1 if Controller

has no operator devices.
To Start/Stop Switch Terminal 4 (Wire

151) if Controller has operator deĆ

vices.

Figure 1. Fuse Kit Connections.

DC2Ć50 Series:

ă1. Disconnect and lockout all incoming power to

the DC2 Controller.

ă2. Place the fuse holder over the preĆdrilled holes

on the chassis and then install using the two

taptite screws provided in the plastic bag with

this kit.

ă3. Remove the jumper wire between L1 and 51.

ă4. Using a flathead screwdriver, connect the wire

labeled 51" to terminal 51 of the Controller.

ă5. Cut the lug from the end of the fuse kit wire laĆ

beled L1" and then strip 0.5 inch of insulation

in preparation for connection.

ă6. Using a flathead screwdriver, connect the wire

labeled L1" to terminal L1 of the Controller.

ă7. Install the fuse into the holder.

DC2Ć60 and DC2Ć80 Series:

ă1. Disconnect and lockout all incoming power to

the DC2 Controller.

ă2. Use aphillips head screwdriver to remove the

four (4) screws from the faceplate of the ConĆ

troller.

ă3. Place the faceplate on the side of the Controller

to gain access to the preĆdrilled holes located

above the grounding bar.

ă4. Install the fuse holder assembly on the chassis

above the grounding bar (below the Regulator

board) using the two taptite screws provided

in the plastic bag with this kit.

ă5. Remove the jumper wire between L1 and 51.
ă6. Using a flathead screwdriver, connect the wire

labeled 151" to terminal 51 of the Controller.

ă7. Using a flathead screwdriver, connect the

jumper wire (labeled `L1') to terminal L1 of the

Controller.

ă8. Install the fuse into the holder.
ă9. Place the faceplate on the controller and then

install the four screws removed in step 2 of this

procedure.

DC2Ć70 and DC2Ć90 Series (DC2Ć71, DC2Ć78,

DC2Ć91 and DC2Ć98 are not included):
ă1. Disconnect and lockout all incoming power to

the DC2 Controller.

ă2. Use aphillips head screwdriver to remove the

four (4) screws from the faceplate of the ConĆ

troller.

Advertising