Rockwell Automation SA500 Drive Configuration and Programming User Manual
Page 37

Configuring the UDC Module’s Registers
3-5
Table 3.2 – UDC Module Dual Port Memory Register Organization.
Registers
Function
0 - 23
Rail I/O port registers
24-79
System Use Only
80-89
UDC/PMI communication status registers for drive A
(monitor only)
90-99
System Use Only
100-108
Command registers for drive A
109-149
System Use Only
150-199
Volatile gain registers for drive A
200-221
Feedback registers for drive A
222-299
System Use Only
300-599
Application registers updated every scan for drives A and B
600-999
System Use Only
1000
UDC module test switch register
1001-1017
UDC module meter port setup registers
1018-1079
System Use Only
1080-1089
UDC/PMI communication status registers for drive B
(monitor only)
1090-1099
System Use Only
1100-1108
Command registers for drive B
1109-1149
System Use Only
1150-1199
Volatile gain registers for drive B
1200-1221
Feedback registers for drive B
1222-1299
System Use Only
1300-1599
Application registers updated every Nth scan for drives A and B
1600-1999
System Use Only
2000-2010
Interrupt Status and Control registers for drives A and B
2011-2047
System Use Only