Rockwell Automation SP200  Input Mains Filter Model Number S20-MF1-Y014, S20-MF1-45P0, S20-MF1-49P5 User Manual

Page 2

Advertising
background image





SP200 Input Mains Filter Specification Table

Mains Filter Module

S20-MF1-Y014

S20-MF1-45P0

S20-MF1-49P0

Input Voltage, Frequency

1~ / 200-240V

3~ / 200-460V

3~ / 200-460V

Rated Current

14A 5A 9A

Operational Range (V), (Hz)

180-265V, 48-62Hz

180-506V, 48-62Hz

Power Dissipation (W)

10 W

5 W

8 W

Leakage Current (mA)

Acc.EN60950 Fault Method

3.5 mA

30 mA

30 mA

Weight (kg)

0.80 kg

0.48 kg

0.48 kg

Protection Class

IP

20

Operating Temperature

0°C TO 50°C

Storage Temperature

-25°C

TO

85°C

Relative Humidity

0 TO 90% (Non.Condensed)

Vibration

1.0 G Operational - 2.5 G Non-Operational

Shock

15 G Operational - 30 G Non-Operational

Altitude

1.000 m (3.300 ft.) without derating, consult factory for derating

information

EMC Standards *)

EN61800-3

EN 50081-1 (Residential and Commercial Environment)

International Standards and

Approvals

CE Low Voltage Directive

*) Tested with a maximum motor cable length of 25m. Practical results may differ.

Input Mains Filter

A

B

C

D

E

F

G

H

Module

S20-MF1-Y014

182 (7.17) 75 (2.95) 47.5 (1.87) 163 (6.42)

60 (2.36)

M4.5 X 6.5

(0.18 X 0.26)

M4.5 X 6.5

(0.18 X 0.26)

200

S20-MF1-45P0

182 (7.17) 75 (2.95)

35 (1.38)

163 (6.42)

60 (2.36)

Obround hole

Obround hole

(7.87)

S20-MF1-49P0

182 (7.17) 75 (2.95) 47.5 (1.87) 163 (6.42) 60

(2.36)

(2

places) (2

places)





Printed

in

U.K.

D2-3420

July

1998