Rockwell Automation 60-2072 PHOTOcountSWITCH Totalizer Series 5000 Accessories User Manual

Page 2

Advertising
background image

2

Installation

1. Remove the cover

Œ from the 42MTB Terminal Base 

(Figures 1 and 2).

2. Remove four (4) screws from cover.

3. Install output module

Ž into terminal base . Note location

of the two holes for the Totalizer contact pins (Figure 1).

4. Mount #60--2072 Totalizer

 onto the 42MTB Terminal

Base so that the contacting pins

 fit into the two holes in

the output module

Ž (Figures 2 and 3).

5. Set the internal reset disable switch in the desired position

(Figure 3).

6. Remove backing paper from vibration pad (supplied) and

apply to the side of the cover as shown in Figure 4.

7. Replace the cover

Œ using the longer (4) screws “

supplied with the #60--2072 Totalizer.

42MR

Photohead

Output

module

Ž

Two holes for

contact pins

42MTB

terminal

base





#60--2072

Totalizer

42MTB

cover

Œ

“

(four) cover

screws

External

Reset

Six-digit display

Figure 1: Photoelectric sensor assembly

Figure 2: #60--2072 PHOTOcountSWITCH assembly

Figure 3: #60--2072 PHOTOcountSWITCH Totalizer

Figure 4: Vibration pad installation

Contact

pins



(Rear View)

Reset disable

switch

Lithium

battery

(Front View)

Locate vibration pad on inside of cover as shown

Cover

locating

holes

(Top)

Advertising