INSTRUCTION MANUAL DĆ3955

ACCESSORY

MĆCONTACTOR ADAPTER KIT

MODEL NUMBER 14C470

ASSEMBLY DRAWINGS 705388

The equipment described below should be installed only by qualified electrical maintenance personnel

familiar with the construction and operation of the equipment and the hazards involved.

DESCRIPTION

The Contactor Adapter Kit provides a means of conĆ

necting the optional userĆsuppliedM contactor (and

optional userĆsuppliedreversing M contactor) to the

optional Basic FlexPak Plus Controller 14C320 thru

14C325 which is suppliedwithout the auxiliary panel.
The Kit is an assembly consisting of an Auxiliary MountĆ

ing Bracket, a power terminal strip, two wire harnesses

andfour screws anda pilot relay.

INSTALLATION

WARNING

BEFORE ATTEMPTING TO INSTALL THIS FLEXĆ

PAK PLUS MODIFICATION KIT, DISCONNECT

AND LOCK OUT ALL SOURCES OF INCOMING

POWER TO THE CONTROLLER.

1. Orient the Auxiliary Mounting Bracket (Refer to FigĆ

ure 1) over the Basic Controller aligning the mountĆ

ing holes. Secure the Bracket with the provided

washers andscrews. Make sure the washer teeth

are firmly embedded in the Chassis to provide

proper ground.

2. Connect user supplied115VAC, 3 amp max power

to 188Ć189 on pilot relay PC. Now connect the

orange lead(139) from the pilot relay harness to the

controller regulator printedcircuit card(refer to FigĆ

ure 1.)

3. Wire the optional userĆsuppliedM contactor (and

optional userĆsuppliedreversing contactor) to the

kit terminal strip according to Figure 2A or 2B. Also,

refer to Figures 5.8, 5.9, 5.11 and5.12 of DĆ3938 for

additional wiring diagram information.

PILOT

RELAY PC CARD

MĆCONTACTOR

ADAPTOR KIT

BASIC CONTROLLER

POWER MODULE

Figure 1 - MĆContactor Adapter Kit Mounted To Basic Controller

Advertising