Step: 4 install the new fan capacitor and bracket – Rockwell Automation 20D PowerFlex 700H/700S AC Drives Frame 10 & 12 Main Fan Capacitor Replacement Kit User Manual

Page 11

Advertising
background image

Rockwell Automation Publication PFLEX-IN025B-EN-P - September 2011

11

PowerFlex 700H and 700S AC Drives Frame 10 and 12 Main Fan Capacitor Replacement Kit

Step: 4 Install the New
Fan Capacitor and Bracket

1. Secure the new fan capacitor adapter bracket to the fan inverter assembly

using the new M8 x 16 mm hexagonal socket screw and washer provided in
the kit. Tightening torque is 12 N

m (106 lb

in).

2. Secure the new fan capacitor to the new fan capacitor bracket using the

M12 nut and lock washer provided in the kit. Tightening torque is 5 N

m

(44 lb

in).

IMPORTANT

Assemble the adapter bracket using the appropriate mounting
hole as shown in the illustration below.

New adapter
bracket

Use this hole when

installing the adapter bracket
on the right-hand side fan
inverter assembly.

Use this hole when

installing the adapter bracket
on the left-hand side fan
inverter assembly.

Nut

Washer

Bracket

Capacitor

Advertising