Step 13. Route the Reversing Contactor’s 5-wire control harness behind the front bar of the auxiliary mounting

bracket. Connect the harness to the pins marked “REV” at the top center of the drive’s Regulator
board. Orient the connector so that the blue wire (66) connects to the pin labeled “BLU.” Refer to
figure 1.

Step 14. Replace the auxiliary mounting bracket removed in step 3.

Step 15. Verify the wiring of the Reversing Contactor and that all connectors are securely fastened.

Step 16. Reattach the cover to the drive.

Step 17. Apply power and test the reversing capability of the drive.

This completes installation of the Reversing Contactor kit.