1.4 Keypad Buttons with Selection Indicators

18) Show Output Count

19) Show Batch Count and Number of Batches

20) Show Current Rate

21) Show Input Count

22) Learn Mode

23) Make Ready Mode

1.5 Keypad Buttons for Selection Adjustment

24) Gap Minus

25) Gap Plus

26) Suction Length Minus

27) Suction Length Plus

28) Batch Preset Minus

29) Batch Preset Plus

30) Counter Setup Mode

31) Machine Setup Mode

32) Batching Time Minus

33) Batching Time Plus

34) Network Job Mode

35) Reset

36) Potentiometer Speed adjustment

2.1 Machine Setup/Diagnostic Mode

Pushing this key puts the controller in machine setup

mode.

Machine setup mode provides a method to view and

optionally change operating parameters for the controller.

The decimal points in the large display (1) will move from

side to side to indicate that various parameters may be

changed. In this mode, the small display gives the selected

parameter number, while the large display (1) shows a

parameter value. The suction length display (3) is disabled.

Parameter Group Selection

The plus and minus keys are used to select the various

parameter groups: machine setup parameters, machine

monitor parameters, machine diagnostic parameters, knife

status parameters, and machine usage parameters.

Parameter Selection within a Group

If the large display (1) decimal points are moving, this

set of minus and plus buttons will select the machine

parameters within each group, see tables 1-6.

Select Parameter Adjustment

If the large display (1) decimal points are moving, this

set of minus and plus buttons will move through the set of

values for the selected parameter, see tables 1–6.

+

+

+

2.0 Run Mode Functions

After turning on the main switch, thecontrol automati-

cally runs a self test. During this self test all displays and

indicator lights come on for approxmately 4 seconds. After

a successful self test, the display reverts to the previous

count screen active before power shutdown. In this mode,

various job parameters can be displayed on the large display

(1) and the small display (2) shows the gap length. The

suction length display (3) is active in this mode and shows

the suction length as a percentage of sheet length.

The DCT500 mode select keys perform the same

function in all modes, except Counter Setup. This allows a

user to quickly switch between the operating modes on the

counter. Select Make-Ready is not a mode unto itself, but

rather is a modifier to all modes.

During the self test operation, do not press any

button. Pressing of a button will cause an error

message to appear in the main display.

!