7 - 29 TROUBLESHOOTING AND ROUTINE MAINTENANCE

7

Clean the primary corona wire inside the drum unit by gently
sliding the blue tab from right to left several times. Return the
blue tab to the Home position (

) before reinstalling the drum

unit and toner cartridge assembly.

8

Reinstall the drum unit and toner cartridge assembly and close
the front cover.

Corona Wire

Tab

Home Position(

▼)