Bird Technologies AT-800-Manual User Manual
Page 45
 
Measure Match
27
Auto Scale
The units scale changes and the Antenna Tester 
begins sweeping.
Manual Scale
The cursor will blink on the minimum scale value and 
Manual Scale will be highlighted.
a. Enter the desired value using the
numeric keypad or change the value 
using the UP/DOWN arrow keys.
b. Press the ENTER key. The cursor will
blink on the maximum scale value.
c. Enter the desired value using the
numeric keypad or change the value 
using the UP/DOWN arrow keys.
d. Press the ENTER key. The tester will begin
sweeping.
Note:
If out-of-range values are
entered, the minimum (if under-range) or 
maximum (if over-range) value will be sub-
stituted. If the maximum value is lower 
than the minimum value, the cursor will 
blink again on the minimum value waiting 
for a correct entry. The actual range 
depends on the units selected.
Note:
Using the arrow keys will keep
the acceptable range. If it is unknown if the 
larger value should be at the top or bottom 
of the scale, press the auto scale key to see 
where the software puts it.